Declaration Of Compatibility

Grounding Pad conformity

Download

Cardiology Chart Paper

Improved Contact Quality Monitoring

The new TWIN sling makes the "split" more than 3 times longer and extends along the circumference of the conductive area. This avoids the hitherto customary concentration of the CQM current in the center and the surveillance function becomes evenly efficient over the total area of the electrode.

Optimized HF-Current Symmetry

The revolutionary "sling design" of the TWIN-SAFE makes it possible for the first time to use efficiently the symmetry surveillance of last-generation devices fully and completely and with arbitrary electrode orientation. The typical symmetry deviation of the HF current is below 5 % with any orientation of the TWIN-SAFE.

Oval Design

Diathermey pads can be applied in any direction due to the oval design.

Unique interwoven geometry

Reults in a more symmetrical current distribution over the two halves

Elongated Split Design

No heavilly concentrated areas of current (edge effect) thus reducing the chance of patient burns.

Unique Interwoven Geometry

Any decreased skin contact causes a change in the impedance ration between the two halves

Item # Pad Use Size (length / width) Total Adhesive Surface Conductive Surface Impedance @ 600kHz approx. Temperature rise (60sec) Cable Length Connector Spec Sheets
6000808N Adults & Children 176 x 122 mm 169 cm2 110 cm2 1,5 Ohm <5°C / 700 mA n/a n/a Spec Sheets
6000810N Infants & Prematures 181 x 76 mm 77 cm2 37 cm2 4 Ohm <4°C / 350 mA n/a n/a Spec Sheets
6000845N Adults & Children 176 x 122 mm 169 cm2 110 cm2 1,5 Ohm <5°C / 700 mA 3m Valleylab REM Spec Sheets
6000846N Adults & Children 176 x 122 mm 169 cm2 110 cm2 1,5 Ohm <5°C / 700 mA 3m Jack Connector Spec Sheets
6000847N Infants & Prematures 181 x 76mm 77 cm2 37 cm2 4 Ohm <4°C / 350 mA 3m Valleylab REM Spec Sheets

Download our Grounding Pad Compatibility information here.


If you need assistance, do not hesitate to contact our knowledgeable customer service department at +44 1803 860100, or contact your local Sales Rep.

Terms of Use | Privacy Policy | Conditions of Sale | Site Map | Return Policy | Code of Ethics

Copyright Nissha Medical Technologies. All rights Reserved.

The OEM trademarks identified herein are the trademarks of the respective OEMs, and not Nissha Medical Technologies. Nissha Medical Technologies disclaims any affiliation, connection or association between it's products and those of the respective OEMs.