Nissha Medical Technologies | Healthcare Solutions Grounding Pads (Diathermy Pads / Neutral Electrodes)

SWAROPLATE - single-use Grounding Plate (Diathermy Pads / Neutral-Electrodes) for HF-surgery.

All Nissha Medical Technologies | Healthcare Solutions Grounding Pads (Diathermy Pads / Neutral Electrodes) are made of 1mm PE-Foam and contain a medical grade acrylic adhesive or hydrogel on the aluminum foil. Pads are available in adult, child/infant and premature sizes. They also come as a single plate, split pad, or with preattached cables. Custom grounding pads are available upon request.

Declaration Of Compatibility

Grounding Pad conformity

Download

Grounding Pad Literature

Grounding Pad Electrodes

Download

Grounding Pad Anatomy
Hover over the dots to learn about our Grounding Pads

The revolutionary "sling design" of the TWIN-SAFE makes it possible for the first time to use efficiently the symmetry surveillance of last-generation devices fully and completely and with arbitrary electrode orientation. The typical symmetry deviation of the HF current is below 5 % with any orientation of the TWIN-SAFE.

These electrodes are for applications with HF - surgery devices which support a Contact Quality Monitoring (CQM)

Pre-attached grounding pads are pre connected with a cable for the connection between the HF Surgery Device and the neutral electrode. Simply select the right type of cable for your device for instant application.

These electrodes are for standard applications with HF - surgery devices which have no Contact Quality Monitoring (CQM).


The advantages of SWAROPLATE Diathermy Pads / Neutral Electrodes:

  • Stays in place - The adhesiveness of the foam border and of the conductive gel make sure that the electrode will not come off. This means that there is practically no danger of burnings with SWAROPLATE
  • Ready to be used - Just remove the protective sheeting and apply the electrode on the prepared skin. There is no additional gel required!
  • Highly flexible with excellent skin compatibility - Gel and adhesive foam are tolerated even by a sensitive skin. There is no gel left on the skin after the application

SWAROPLATE Diathermy Pads / Neutral Electrodes

  • A list of compatible HF-surgery devices is available.
  • Meets the requirements of IEC 60601-2-2:2009.
  • For correctly applied electrodes the maximum temperature rise under standard load according IEC 60601-2-2 is typically < 4°C. Limit according to the standard is < 6°C.
  • NE contact-impedance is typically 1 Ohm (for adult size electrodes).
  • Shelf life is 24 months in the originally sealed bag.